If your pilot light is simply blown out, you should have no problem retaining the flame when you relight it.
1. What would cause a pilot light to keep going out? Start by turning your water heater thermostat to the lowest setting or off. Often the manual includes instructions for reheating the pilot light. Read on for reasons why, and what you can do to fix it. Step 10: Enjoy Your Warm Water, Or Ask For Help! Locate the igniter button and keep depressing it while pressing the gas control knob all the way in. Hot Point furnace repair experts guarantee integral and trustworthy repair services.
Learn more about a furnace tune- up here! Have a manual for
Dont forget to use a torch light to illuminate the dark area so that a single speck of dirt cant escape. As a result, you cant get any hot water from the water heater because the pilot light wont stay lit. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. If needed, replace them. Relight the pilot and confirm the water heater is heating the water as expected. Contact your utility company immediately. Explore more reasons for why your furnace won't turn on here!

If you have gas appliances in your home, then you have a gas regulator outside your home. Newer model water heaters will have a pilot setting on the gas valve and a spark electrode to light the pilot.

But What If You Don't Have A Manual Igniter ? This can happen on excessively windy days or nights. Hot Point Heating and Air Conditioning offers flat rate pricing on all of our Wisconsin repairs, meaning we charge exactly what we quote and dont stray from it. Next, unthread the nuts or screws securing the burner plate itself. We know that a home with no heat or hot water is the absolute worst! If you think that the burner isn't on because you can't hear the familiar sound, remove your cover plate to confirm that you can't see the burner firing. It is not unlikely for excessive wind or a nearby draft to extinguish your pilot light flame.

Keep me posted. A clogged intake can cause the thermal button to trip. In order to access the intake you will usually need to remove the combustion door. After logging in you can close it and return to this page. Gas water heaters which use a pilot to light the burner will also have a thermocouple or thermopile to monitor the pilot (a thermopile is, essentially, multiple thermocouples connected in a series making the component more sensitive than a single thermocouple). That dang pilot light keeps going out !!! You can't post conmments that contain an email address. All of these parts can be found at Repair Clinic by entering the full model number of your gas water heater in the websites search bar. Reattach the burner supply tube to the valve, as well as the pilot supply tube if necessary. A dirty pilot orifice will prevent your pilot light from staying lit. Thread and tighten the mounting nuts or screws to secure the burner plate to the tank. Reseat the burner assembly in the tank, making sure to rest the burner tube in the bracket if applicable. The difference is that you're now going to go up 10 degrees to 20 degrees higher than your desired temperature. There will be a gas panel where you can see if the pilot flame is lit. Standing pilot lights are common in older furnaces, but many newer furnaces have intermittent pilot lights or hot surface igniters. Main Office: 9590 Deereco Rd, Lutherville-Timonium, MD 21093, Columbia Office: 9123 Route 108, STE 305, Columbia , MD 21045. Click "Add" to insert your video. Complete. Be aware, you may need to detach the thermocouple from the burner assembly to clean it thoroughly.

Follow that small tube and you should find the location of the pilot light. Why can't I light the pilot light on my water heater? Your thermocouple is the sensor that measures temperature. You will need to take off the front of the furnace to get proper access. Hold down the pilot button on the gas control valve to let the air in the gas line bleed and get some gas down into the chamber. The pilot light in your boiler is essential for creating heat. A strong draft can easily snuff out your pilot light. Whenever you light your pilot light and notice a yellow flame, a dirty pilot opening is causing your furnace pilot light to keep going out. Regular maintenance for your furnace, water heater, and boiler is a necessity so that you can ensure your heat or hot water never goes out! If there is a problem with your thermocouple or if it is simply covered in dirt and debris, you may experience pilot light problems. Once you detach every line leading to the gas control valve, its time to pull out the bottom cover panel to access the burner or pilot assembly. The thermocouple is usually mounted on the burner assembly located near the bottom of the water heater tank. 3. Click until you see a blue flame in the gas window of the water heater. Hopefully just the thermocouple. First off, grab a flashlight and a screwdriver before inspecting your furnace. Also, open the main water supply valve or cold inlet water valve. This a button located to the left the gas control valve and is usually red. Spray electrical cleaner in where that end came out of, or twirl up a piece of steel wool to a point small enough, but long enough to go in hole and by spinning it, you can clean surface in hole as well. The above steps will not work for every type of Rheem water heater or for every situation. - Better answers use proper spelling and grammar. Many of the Rheem water heaters have a Vial that is located inside of the combustion chamber. You also have to be careful about not breaking off the pilot or gas fittings when cleaning the rust. Besides, Rheem water heater pilot light wont stay lit if the igniter is at fault or its wiring gets damaged or loose. The thermocouple is an automatic safety shutoff device that prevents the gas valve from opening if the pilot light is out. You may also find that your gas fireplace has a pilot light as well. A pilot light is more likely to be found in water heaters or in older furnaces and boilers. Dirty or Damaged Thermocouple Explains Why, Weak Gas Regulator Can Make Pilot Light Keeps Going Out, Step 1: Use and Refer to Boiler's Owner Manual, Step 5. If there is dirt and debris accumulation in the gas chamber, air cant flow into the chamber. You should be able to heat your home now! Best way is to remove it, and clean it with fine steel wool, or fine emery cloth, at both the probe end that sits over pilot flame, as well as undo it from gas valve and rub contact surface on other end with steel wool as well, and if you have any electrical cleaner, give it a squirt in spot where thermocouple was removed from, and clean it out well, and if no electrical cleaner, roll a piece of steel wool up small enough to get it in that hole and twist it on the surface where thermocouple meets, to clean the surface . Reconnect the wires to the gas valve and, if applicable, secure the thermocouple to the valve. Make sure you have an adequate fuel supply, you may need to contact your local utility for a free inspection. I recommend you do it yourself if you are electrically inclined to save the labor cost.
rheem Open Boiler and Locate Pilot Light, Step 7. Most furnaces have a small valve near the bottom of the furnace. There are several things you can do to trouble shoot your water heater. After waiting 5 minutes turn the gas valve to the position PILOT. You should continue to hold the reset button for an additional 20-30 seconds after the flame is lit. Remember, gas is explosive! Be aware, you may need to detach a pilot supply tube as well.

Start with a visual assessment. Next, identify the gas valve and turn it off. Water Heaters Installed by Licensed Plumber. SOURCE: I too have an issue where our Rheem power vent. SOURCE: rheem gas tankless water heater with error code c4 13. problem is inside burner compartment o2 sensor dirty or block..need to have a qualify technician clean it. If the thermocouple isn't lined up correctly, it won't read the flame, and will shut the valve for the gas. And it's ruining everything you had planned today! - Provide details, support with references or personal experience. So much for all the cleaning, laundry, and hand washing that needs to be done! You have a gas regulator outside your house if you have gas appliances. A leak in the output duct of the furnace could cause air to blow into the area. If your flue pipe is loose, cracked, or not properly connected to the furnace, excess wind could enter through the holes and extinguish the pilot light flame. Tell us some more! Locate the copper rod near the burners. Then, this heat warms the air brought into your furnace, which will be redistributed throughout your home. Now, follow the below steps to relight the pilot: You cant light the pilot light on your water heater if the thermocouple is bad. Inspect Flame. The thermocouple detects when your pilot light is burning.

This time, start by switching to "vacation" or "low" mode. You can now pull the burner assembly away from the tank to access the thermocouple. Next, hold the reset button down. Additionally, depending on the appliance, a pro will evaluate the gas valve, all of the connecting piping and wiring, flue venting, and all other functioning parts of your appliance to ensure each part is operating at maximum efficiency.
heater thermocouple rheem furnace ect repl thermocouple zoro rheem Before you begin, be sure to unplug the water heaters power cord and shut off the gas supply. Start doing it yourself with the confidence that comes with 100+ years of experience. How To Clean the Thermocouple on a Water Heater. Wait about 10 minutes to make sure there is no leftover gas in the pipes. If thermocouple is from ordinary tank-type water heater, then it is a generic part with different lengths 15" 17" 21" 24" 30" available at hardware of home center. The only thing more frustrating than a busted furnace is the hundred trips to the garage for tools when you're trying to fix it. But, if your gas water heater has an igniting button, press that instead. Next step would be a new gas control valve, so lets try the cheap and easy first.

And if you have no heat check to see if your furnace or boiler pilot light has gone out. The pilot light is a small flame used to ignite the gas burner on your water heater. At the base of your gas water heater, you will find an access panel directly beneath the thermostat.