t104 intermatic t103 waterheatertimer intermatic t104 inyopools 115v t104m timer intermatic t104 wiring amp paragon 240volt voltage controls phase any wire you can short out the brand new timer and burn out the breaker to. A: use the lever to make it crispy, not like its full of molasses. Tighten down all brass screws securely, to hold all wires firmly in place. Posted: 5/22/2017, Anonymous intermatic t104 timers t101 Tighten them with a wrench. Inside the Intermatic T104 box, remove the black plastic insulator. This will disengage the dial and allow you to spin it in either direction. I guess if they look the same as before maybe the dial is warped? pool timer not turning on or off? has your oly beer barrel stopped moving? For a better experience, please enable JavaScript in your browser before proceeding. You sound like a fairly capable DIY'er who is familiar with these T104s. I completed the process to replace the clock motor for our waterfall pump in our pool, which had been hit by lightning I'm guessing. After securing the wire conduit (flexible or rigid) to the box knock out with the proper 3/4 conduit connector, connect the Load 1 and Load 2 wires (going to the pump, or the Load), to terminals #2 and #4. I was able to do this myself. After securing the wire conduit (flexible or rigid) to the box knock out with the proper 3/4 conduit connector, first secure the green ground wire to the green ground screw, shown as GR. Of course I threw out the old motor when I hooked it up and saw the gears moving and assumed the dial would move too. Does this mean I am not getting power to the timer altogether or does the manual switch become nonfunctional if the timer blow is out? 2022 JNews - Premium WordPress news & magazine theme by Jegtheme. If the circuit breakers are clearly off, it is probably safe to grab the entire machine and take it out of the box, but start with a power meter set to AC to make sure the power is definitely off. A timer that switches on and off at the wrong times usually occurs after a power outage. is your rolling ball clock not working? Heres a short (2:36) video of that very thing happening to Rob, inCheck-up & Set-up of an Intermatic Time Clock for Pool Pumps. motor intermatic t104 clock replace step inyopools Watch these tips and tricks to make sure the timer is in fact working before your replace it. Note: the first terminal is not labeled. Can you help how to check where it's broken or what needs replacing? Electricity is dangerous and can kill you if you dont know what youre doing. Regarding the power, it's good to mention that there are two boxes on the house, one for the 110 volts and the other for the 220 volts. Posted: 8/12/2016, mdavis99 In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. Create Device Mockups in Browser with DeviceMock, Creating A Local Server From A Public Address, Professional Gaming & Can Build A Career In It. Fairly inexpensive repair and easy to do. If its working in bypass then there is probably something wrong right out of the box and you should just exchange it. Posted: 5/20/2017, InyoPools Product Specialist Dennis R. If you are unsure, the white (neutral) wire is often connected to the neutral bus in the switch panel, and the black wire (line) is connected to the signal switch. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Posted: 6/23/2014, InyoPools Product Specialist Dennis R. It could also be loose wires, either on the time clock terminal board, or on the timer motor. You will have live wires exposed and they can kill you if you touch them. For the wires that connect to the pump, or the Load, also connect the Green to GRD and the White (Neutral) to terminal A. Only perform this step if you are qualified. to adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. We are a registered 501(c)3 non-profit that is funded by user donations. They should be straight, if not, replace them. jwaer - Sounds like the dial is turning correctly, just that the ON tripper isn't engaging. Take them off and inspect them and look for twists in them. Like Pablo, I also needed a small star screwdriver to remove the old motor from the back of the timer. It is likely the intermatic will be connected to the 220 volt box. There is a small spring behind the screw that may have rusted or broken. If power is reaching the clock, and the gears are turning, but the dial is not turning this could mean that the gear on the back of the dial has not engaged. It is being practiced by thousands of pool owners just like you. The gears seem to be spinning faster? Please click here to view IntermaticTimers. A: Break out a can of your favorite ant spray, and let em have it. And yes, the WG1573-10D Clock motor is a compatible replacement for a WG1573-5. With a small Phillips head screwdriver, remove the two screws the fasten the clock motor to the mechanism. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. TURN OFF THE POWER TO THE TIMER BOX. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. It's like having a new timer. Place the T104 mechanism on a smooth flat surface with the yellow clock dial facing up. Remove the two screws, from terminals 1 and 3, that secure the two white clock motor cables in place. sunplay intermatic t104m intermatic t104 timer wire t101 Previous comment in order to get email response. The pump turns on and off manually just fine.. The motor wires should be connected to the input terminals 1 and 3. Flips On And Off Damaging Equipment. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. Secure wire conduit to the knock out with the proper conduit connectors and first connect the green ground wire to the green ground screw labeled GRD. It's an old house and an old timer, and the information on what tYpe of timer it was (220 or 110v) was unknown. If I have to tell you which terminals to measure, you shouldnt be doing this! A:If youve gone through a full inspection of the mechanism and determined the motor or gears are bad, replacing a timeclock mechanism is an easy repair for a qualified person. Switch the breaker off at the power board. timer t104 intermatic pool t101 t103 timers volts 115v waterheatertimer Pool Timer Not Turning On Or Off!! dpst 277v intermatic T104 Clock Motor - It sounds like one of your motor wires is going to a load line. A: The center time pointer the one that says DONOTUNSCREW? hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. You can find this in your power board. Thanks. intermatic t104 40a dpst Copyright 2022 INYOpools All rights reserved, How To Replace an Intermatic T104 Clock Motor. With a flathead screwdriver, loosen the screws that hold the ground cables and power cables in place. intermatic In past cases, a good pic or two have helped the experts to evaluate the issue. The timer quit after a nearby lightning strike. The most common pool timer used for inground pool pumps is the Intermatic time clock. You will get much more visibility by. Anonymous It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. When it barely moves, check the wires leading to the timer to see if it is possible for current to reach the timer. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. You can replace it but its really just easier to replace the entire mechanism. Reset the clock to the correct time. Faulty Pump or Wiring from the Timer to the Pump. Posted: 10/5/2015, jwaer I would try replacing the timer mechanism. The Intermatic WG1573-10D clock motor should now be successfully installed if the yellow clock dial is turning. Except in my case when its manually turned on, the dial turns!!! AJH Trade Group also participate in other affiliate programs. If the light still goes out to turn on, the lamp may have actually burned out. If you replaced the timer mechanism, you should have solved any problems with the auto on/off not working. This is a 208/277v motor. They are fairly straight-forward, but once in a while we do see some unusual wiring scenarios. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Replace the plastic insulator cover, turn on the power and observe the visual motor check. Here's a link to our guide on "How to Replace an Intermatic T104 Mechanism". Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. A: Use a large small flashlight to look at the engine control window next to the first timer gear. But then again, Intermatic timer motors can be half the cost of a new mechanism, depending on the model. watch as i find the solution and am this is the second one ive bought that does the same thing. I have a T104. Even though my timer was not wired exactly as the one in the instructions, I was able to figure out how to do the job. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Set the full current time on the middle hand of the era, pointing to five oclock. the switch is not being triggered on just off. Theres really only 3 causes as to why your pump wont turn on/off. It should sit down nicely. Posted: 8/10/2016, 92Keywest Heres a real nice pictorial on how to replace an Intermatic timer motor, or mechanism. Q: My Time Slot Manual Lever Is Hard To Turn. Intermatic time clock motors can be replaced, but unless the time clock was fairly new, Id probably just replace the entire Intermaticmechanism. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. Posted: 8/12/2015, InyoPools Product Specialist Dennis R. Posted: 6/13/2017, J. Johnson You don't really need to disconnect all the wires shown in Step 3; just terminals 1 & 3 which connect to the timer. I dont see any debris blocking the off dog. If its not, it wont work properly. Set the current time to the center time pointer, pointing downward at 6 oclock. Make sure the middle time pointer is tight. Turn the mechanism over to the backside and locate the clock motor. Greg G - It sounds like your need to replace T104 Mechanism. Sometimes its way quick just to replace it rather than spend hours troubleshooting. Download this software and fix your PC in minutes. Anonymous (125V motor) - Unfortunately, a 125V timer motor will not work in your T104 timer. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. With the power switched off at the breaker, take out the main part of the timer and carefully inspect the gears for obstructions and missing teeth. If they are not moving then you have an issue. Please clickhere to view the IntermaticTimer parts. A: If using 120V timer or model T101, there are 3 metal screws under the hard plastic insulator cover (terminals). In fact, it can take less than 5 minutes. All seemed well, the first morning, the waterfall came on pretty close to 7AM like I had set it and shut off around 9AM, also based on my setting but that's when the wheels came off the bus. When the timer car is refilled, you will be able to perfectly see the passages through the toy car. Intermatic timer motors can be replaced, however if the timer is really new I would probably replace the specific Intermatic mechanism entirely. A: The lever action should be crisp, not like its full of molasses. If it does run, the gears in the timer may be binding under load. They have 220V on them. i made sure the trippers were fully inserted and tight. I recently had a company come and service my timer, because the pump would not turn on/off automatically. intermatic t101 timers Also check that you have 240V coming into the timer. Does this mean I need a new T104, or is there a replacement manual on/off switch? If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. Any ideas on what the problem could be? After placing conduit (flexible or rigid) on the box, rule out sufficient reason for the correct 3/4 conduit connector and first attach the green ground wire to the ground The covered ground screw indicated in the direction of GR. Posted: 6/21/2016, Louie Replace the lamp with a new one. Only cost me $25 for the part. intermatic t104 timer wire t103 t101 On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Back when I was a young technician I was taught to always look for the easy things and use all my senses. intermatic t104 t101 t103 terminals timers waterheatertimer The gears move on the new motor, but the dial does not turn. Then, remove the timer mechanism to access the motor. Perfect instructions, even a girl did it!!! 3r intermatic rainproof When the watch is powered on, the gears rotate, but this dial does not rotate. intermatic t104 40a dpst Replace the material insulating cover, turn on the power and visually observe the motor control. when you test the timer, place one probe tip on the ground wire or metal case and one probe on the a, 1 or 2 terminals. This is the first step to confirm if there is power or not. Finally my screws were not phillips but one with star heads. Any new postings here are unlikely to be seen or responded to by other members. For added safety, turn off the dedicated pool switch in the main building as a switchgear slot and block the snowboard or lay down a large piece of paper so that someone else cannot turn the switch (s) back on for a while. intermatic t104 intermatic fixya please help me. I bought the 1573-10d 208/277 hz. However when the timer is in the off position, there is no gear movement at all which means the clock isn't moving. Close the timer door and continue to enjoy the energy savings of using a timer. Intermatic timers are a great addition to your pool set up but they can go wrong. Grab it, pull it towards you, move it around then place it back down. Replace the gears if this is an issue. The old unit did have some bad gears that seemed to be lock-up, But I could see the motor turning on that unit as well.. T104 is a 220V timer. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears (I once found a gecko tail), or the timer motor has burned out. Put them back on and tighten them. Posted: 12/12/2018, InyoPools Product Specialist Dennis R. Just above the yellow clock youll see some holes. Before using the timer strategy or touching the wire with another screwdriver. I made sure the trippers were fully inserted and tight. Heres a perfect list of some of the support calls Ive made over the years. Now remove the terminal cover on the timer. Pull the cables away from the Intermatic mechanism. Connect the ground wires to the green screw located on the Intermatic timer mechanism. If any of these issues occur your timer will not work properly. This is hard to check if you are not qualified. A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. How to adjust the timer wheel on intermatic pool timers. This causes the time to be incorrect otherwise, it is working. intermatic pool switch fireman wire timer t104 heater timers volt waterheatertimer plastic box Should I get a volt meter to test it? t104 timer intermatic wiring control wire diagram freeze t101 t104 intermatic t103 waterheatertimer You are using an out of date browser. I believe its the manual on/off switch that is the problem. I have the same problem. make sure it hasnt tripped and is switched on. Turn the mechanism over and place one white cable onto terminal 1 and the other onto terminal 3. Most visitors online was 3404 , on Jan 24 2020, Texas, San Antonio/Marion, South-Central Area, Breaker flips when Intermatic timer starts, Intermatic timer replacement and wiring fix, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Posted: 5/2/2017, Greg G The next morning it was before 6AM, after a few days, it is coming earlier and earlier! You may encounter an error code that indicates issues with troubleshooting Intermatic Timer. intermatic t104 timer wire t103 t101 Any idea what may be causing this? So don't wait any longer - download ASR Pro today! intermatic t104 timer t104 intermatic pool t101 t103 timers volts 115v waterheatertimer Pleaseclickhere to viewIntermaticTimers. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. It should be 110V or 220V AC. Check that your supply lines are going to timer terminals 1 and 3 and the ground wire is attached to the ground lug. t104 intermatic Install a new hourglass mechanism and replace the wires in the direction of the previous configuration. Since you are a new member, your photo upload capability may be limited. It only takes a small amount of dirt to foul up gears so look carefully. It should loosen up after a few goes when the grease and gunt dissolve. A:To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward, towards you. Jump to the troubleshooting steps below to fix the issue. If it doesnt, there could be an issue with the clock face or gears. You can apply WD-40 to the back of the scale, to the arm, and also to the gear motor. I have an intermatic T20004R and my timer is working because it is keeping the correct time. Just kidding, helpBut maybe this atmosphere could be vague? Clean the gears with a toothbrush if you see debris or gunk in them. Any chance you can post a pic or two of the wiring in question? Take the motor off the back and run the timer with all the wires connected to make sure the motor is running. Posted: 7/7/2015, Anonymous Posted: 10/24/2014, CB If you cant, is the manual switch stuck or jammed? Posted: 2/5/2016, InyoPools Product Specialist Dennis R. Other smaller problems are more common, heres a list of some service calls Ive gone on over the years. Please consider. If the pump comes on, you definitely have power to the timer. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. Hi Rich, is one of those wires (white?) Posted: 7/3/2013. If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. As an Amazon Associate we earn from qualifying purchases. A: Is the focus time arrow the one that says I am not twisting? Posted: 10/30/2013, Mrs. Faniaska Swimming pool tips, reviews & how to mrdgvb1 on june 2, 2013 at 4:31 am. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. Activate the minimum manually using the Minutter switch. If not, use the circuit breaker to make sure the watch is plugged in, turn it on, then turn it on again. Now try to jiggle it on and off. can you help me figure out why? Keep the box latched, and use conduit connectors to seal up the knock out holes. Now that you have it out take it back to Home Depot or wherever and exchange it for another one and see if that works. The old motor was a WG1575-5 and so was the new one. Turn the manual on/off switch. Thanks for reading the counter! Herea few thoughts on how best to tackle the pool wall clock problem and fix or refurbish the highly interconnected pool clock. I also replaced the timer using a brand new unit (all the guts).. I would suggest calling Intermatic and suggesting that idea and a free replacement? Posted: 8/27/2016, InyoPools Product Specialist Dennis R. If this does not improve, the examiner will contact the clock if an insect infestation is suspected. motor intermatic t104 clock replace step inyopools Also, you can try going to the bottom of your quick reply post where it says Go Advanced, and then down to where it says Manage Attachments. Proceed to step 4 to check the timer itself. If the pump doesnt come on, follow the steps below. If your 120V wires are properly colored (and sometimes they are not), the White wire connects to terminal A, and the Black wire connects to Terminal 1. There is a replacement for a 110 system also. If the power is on and the gears are not turning it is most likely the motor. t104 intermatic wire timer mechanism fireman switch You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Pablo - Thank you. One morning I noticed my pool didnt automatically turn off. A: If you have performed a full check of the gadget and determine that the engine or armor upgrades and gun are faulty, replaceThe timer program is easy to repair for a qualified technician. The same happens prior to the timer reaching the off tripper. Posted: 5/18/2016, InyoPools Product Specialist Dennis R. You may need to buy a new timer mechanism. The Loads are what the timer controls. It has to seat into the gears after you pull it out to set the time.into the gears after you pull it out to set the time. I think youve got a screw loose, and you probably pull the tags off of all your furniture too. I'm stumped.. Hello and welcome to TFP! Connect the green ground wire so that the GR screw turns green. Make sure that you have 220V going to your timer and not 110V. You can also find other insects such asAny animals or amphibians who are attracted by the instant watch box. Check out the diagram below, or see the wiring diagram which comes with a new timer, or is printed on the door of the timer box. When you let go of the dial, you want the gears to engage easily. I replaced the timer motor, the timer is keeping perfect time but when it comes time to turn on it won't turn on. Ed - Check out guide again to make sure you have the motor wired correctly. Fear not, my friend, for ASR Pro is here to save the day! We really appreciate your added insights. The mechanism can then be removed by depressing a clip at the top inside of the timer box, just above the mechanism. Or other advice or explanation. Pool pump comes on fine with the on dog, but wont turn off. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. Then take the motor away for the timer gear and see if it runs by itself. How To Fix A Pool Pump Timer (diy Diagnosis And Replacement), Swimming Pool Intermatic Time Clock Diagnosis, Intermatic T101m Pool Pump Timer Not Turning On. t104 intermatic timer wire If that is true I would take out the guts again and inspect for anything that may be causing the problem. Thanks for the instructions [made it simple]. Start with the easy checks. Watch These Tips And Tricks Before Replacing It.