You can reset the propane regulator by turning off the propane tanks and making sure all your propane appliances are shut off. To test the single stage regulator you could use a gas pressure tester like this (click to view on Amazon) to see what the pressure coming out of the regulator is to make sure its correct but if the regulator looks like its in good repair it should be fine. The coach is a 2020 Thor Four Winds 31W. Not sure if it will work but it seems like if the pressure coming from the European tank is higher than what an RV 2 stage regulator can handle the next step would be to try two regulators (1st and 2nd stage) with a more heavy duty first stage than what the common RV 2 stage regulators usually have.
fairview changeover Probably running at about the same time might be the Norcold 1210IM refrigerator which draws 2,700 BTUs per hour. Make sure you tape the same direction you will be screwing on the propane regulator so that it does not move and get undone while you tighten the regulator. Any suggestions or recommendations? The water heater gets a flame but goes out after only a few seconds. This is the lock-up gas pressure. If you hear popping noises when you turn off the flames on your RV stove burner then your propane regulator may be having issues. Also, the second stage regulator cannot be placed before the first, it must come after. If it senses this, it will stop or slow the flow of propane. The first thing you need to do is locate where the leak is. If there is gas leaking out it will make bubbles in the solution. The Automatic Changeover Isnt Functioning, RV Propane Detectors (click to view on Amazon), Best 2 Stage Dual Tank RV Propane Regulators Reviews, Is Your RV Fridge Not Cooling? It only expels gas if I dont use the appliances. The same thing happens when I turn the heat on the AC thermostat. You can check out this article for some of the best RV regulators (click to view) I also have another article with instructions on how to replace an RV regulator (click to view). Also check the pipe to make sure its clear.
propane changeover fairview stage changover switchover If you see bubbles starting to form, that is where the leak is. You can reset the propane regulator by turning off the propane tanks and making sure all your propane appliances are shut off. You can clean a clogged propane regulator using a mixture of water and dish soap: An automatic changeover valve automatically switches from one gas tank to another, when one is empty. It lights like before and wont stay lit.
If it continues to happen there could be a failure in the unit and you may need to replace it. Wait for about 10 minutes then reattach both or one of the propane tanks. You want enough to create a good seal but no so much that the parts wont go back together. If they are mostly yellow you dont have enough pressure in your LP gas system.

I have one propane tank on my RV. It is as if he did not admit the pressure that this European tank has when it is full. I replaced the ignitor batter on the stove and get good spark. I have an American motorhome, but when I restored it I couldnt keep the original Manchester tank and I installed a 100 liter LPG tank (80 useful liters of LPG) and it is European.
tank propane regulator rv dual hose gas stage changeover camping camp Put the water and dish soap in a spray bottle and gently swirl it around to mix. Make sure you use the gas line thread tape when attaching the old pigtails to your replacement propane regulator. 5) Do I need to change the pigtail lines to match? Its one of the few that I could find that ships to Spain. Turn off the propane tank, and make sure all of your propane appliances are off inside your RV. In this guide, we give step-by-step instructions for troubleshooting some of the commonly-reported RV propane regulator issues. I have the fan on high but no heat is coming out of the floor vents. You can also get premixed gas detector spray (click to view on Amazon). 1. Its easy to see if you have lazy yellow flames by lighting one of the burners on your RV stove. There is a Camco horizontal propane regulator on the Spain Amazon store, but that one is made for smaller propane tanks (up to 30 lbs) which means it wont work for a larger #100 tank. Pull the cover off by hand to remove it. RV Propane Regulator Troubleshooting & How to Guide, Gas Fireplace Troubleshooting and How to Guide. 2. Thanks in advance for your help! If it doesnt fix the problem you may need to replace the propane regulator. Mix 1/4 cup of dish soap and water in a bowl. Michael. A two-stage regulator is going to be the best option for a propane fridge. If its an old RV and you notice the flames on the stove acting funny you may want to replace the regulator. Unscrew the leaking connection and clean off the old putty or tape.
propane regulator rv regulators stage changeover camco double I assume that the fan turns on when you turn the furnace on? See Also: Can Propane Regulators Or Propane Lines Freeze? Its connected on 2 30lb tanks on my trailer. No soot build up on exhaust. Furnace started making popping noises. Yes you can, we recently replaced our own RV propane regulator. Your help would be extremely appreciated. Hope this was helpful, good luck with your camper. If you open it slowly it shouldnt activate. It doesnt indicate when the tank is empty (red) any more. Hard to say based on that, but I would definitely try changing the regulator before getting a new furnace. Thanks for your comment, glad we could help. See Also:Is Your RV Fridge Not Cooling?

Thanks! Normally if left pointed straight down the regulator will pull propane from each tank simultaneously which doesnt impede the flow of propane so long as both tanks are open. If so did you make sure the propane regulator was for horizontal tanks and not vertical ones?

i have replaced my furnace with a new core and its still doing the same thing the 20 year old 1 was.it lights 3 times and then goes into lockout.im thinking its a bad regulator but my other lp appliances work.since the furnace uses more propane than the other appliances could a bad regulator let the other ones work but not the furnace? Is that normal or should I replace my regulator? The upstream main gas regulator may be the wrong size or capacity. If the leak is coming from the propane regulator it is possible that it has been damaged and needs to be replaced. You can get a replacement for an RV propane sensor here (click to view on Amazon). It mostly sounds like the propane regulator you currently have is too small like you said, but I could be wrong. Repeat the test until you see no more bubbles. It doesnt restrict the airflow as much and it will stop wasps from getting into your RV. Hi I have a 2019 Grand Design 5th wheel camper with a Furrion stove. To troubleshoot a propane auto changeover valve that is not working, follow these instructions: If your RV flow propane is not flowing, try the following troubleshooting tips to fix the issue: Check this too: Gas Fireplace Troubleshooting and How to Guide. But if the heavy soot continues you may have a bad RV propane regulator. The thing that worked for us is we took off the metal thing covering the exhaust pipe from the furnace on the outside of the RV, also check the exhaust pipe to make sure nothing is inside of it like a wasp nest. Read flowing gas pressure at the pressure gauge or manometer with all of the gas-using appliance pilots lit and appliance gas burners operating. Then evenly spray the mixture or the leak detector onto the connections where there may be a leak. Turned the propane tanks on. Compare to desired pressure.
rv regulator stage changeover propane automatic regulators bracket Next remove all the old yellow gas line tape from the main gas lines threads and re-tape it. We had that exact same problem with our RV furnace not too long ago. If the regulator detects a high propane flow it will engage the safety valve and shut off. This is pretty common with older campers and its most likely whats causing the issues. Hopefully, your leaks will be taken care of after this. A replacement propane regulator that is of the proper size and style for an RV. Also, if you only have one propane tank open and the selector is aimed straight down it could potentially limit the propane output since one side isnt putting out any propane. Thanks for advising me Mr Heater but he is the one that I just placed about a year ago, because I also had the Camco and the same thing happened. It starved for fuel again. Similar to what people install to their homes when they have a large propane tank sitting outside. You could get a new one and replace it to see if that helps or you could take your RV to a dealer and have them test the pressure in the lines to make sure the regulator is adjusted correctly and working as it should.

I had a similar issue, check out this article here for info on a few things you can do to try and fix it yourself. Hi and thanks for sharing. With the propane gas running through the regulator, you then need to inspect the connection between the propane regulator and the main gas line for leaks. Hopefully at least one of these suggestions will help.

Dump or spray it over the regulator and look carefully for bubbles. The regulator needs to be next to the propane tanks because the first stage of the regulator needs to control the pressure right out of the tank itself in order to properly work. Re-light all of the gas appliance pilots and turn the appliance on, confirming that the gas burners are all operating at their highest setting. Propane is a fairly clean gas and it doesnt normally have dark smoke when it burns. The propane regulator is a crucial component of every RV gas system and if it is not working properly you will notice problems with your propane appliances. You can also remove the old pigtails if you are planning on using them on your new regulator.

We had propane for heat and hot water. The fridge and furnace do nothing. This is also where we share our favorite RV and camping-related gear and accessories. Once youve replaced the propane regulator and drained the line as much as possible your problem should be solved. Sf 30 suburban heater running thru the (3) cycles. Ring Spotlight Cam How to & Troubleshooting Guide.

Also, you will need a larger propane regulator for a tank of that size. How To Stop RV Decals From Cracking, Fading, & Peeling, Jackery Releases Official 8mm Extension Cable. If resetting the propane regulator doesnt fix the problem your RV propane regulator is not functioning correctly and may need to be replaced. So I pulled out the solenoid along with the LP gas tray to clean that out as well. To remove it, place a wrench on the nut of the main gas line and twist the regulator.
changeover propane smartrving regulators If the propane tank is not the problem, the regular has gone bad and needs replacing. Here are the top most crucial tests you should always have in mind.

I've checked the 2nd smaller regulator to make sure it was installed the correct direction. Switched bottles across all possible variables; same result. Just make sure you get replacement regulators that match the ones on your RV. If its really old though you may want to replace it anyway just to be safe. Kept the silicone at the edges. As for the last problem, which was gas coming out in the kitchen for 30 seconds after you turned off your tank. The gas thats coming out after you turn off your propane tank is whats left in the lines. Here, we address common problems and questions people like you have to deal with at home on a daily basis. 2) How can you tell if the 30 psi Regulator is defective? If that doesnt solve the problem your RV propane regulator isnt functioning correctly and probably needs replacing. I checked my propane lines and found no leaks but do have a smell coming from the regulator. Theres a little vent on the bottom that causes the smell. If the rubber washer inside looks fine it could be that the nut wasnt tightened enough.
propane rv regulator camco changeover lp gas stage acme hoses kit pressure It is also works a safety feature in case the propane tank is overfilled and the pressure is getting too high. Test every propane connection in your RV by spraying the soapy water on it or applying it with a sponge.
stage rv regulator propane flame king gas kit changeover pigtails Fortunately nothing dangerous has happened at all.
Am I thinking of the right thing to replace? Also, when i disconnected the hose on the outlet side of the regulator a small amount of oily liquid dripped out of the hose. A common cause may be a safety feature that is inside the regulator. it works fine on 12v, 240. So for a quick recap, to fix your problem I would change the propane regulator because it sounds like it is getting old and its probably time to get a new one because its letting moisture into your tank, and also refill your propane tanks with a winter propane mix to make sure any moisture in them gets removed. Have you been able to light the stove before? Its going to be hard to find an exact replacement for that model of propane regulator. But this isnt always the case and sometimes your propane regulator can have issues.